ESD
Last Updated: Apr 9th, 2008 - 15:00:00
|
See this article in our Digital Edition Download a pdf of this article (right click to save the pdf)
Editor’s Note:
This is the first in a series of articles on system level ESD testing.
Subsequent articles will describe the system level testing in more
detail and the issues that need to be considered when designing a
system level test.
The user of an electronic product, whether it is a cell phone, a
computer or a game console, is justifiably upset if they touch their
device, feel a small ESD discharge and then find their prized
possession not working, either temporarily or permanently. The user
will not care that they were charged up to many thousands of volts when
they touched the product, or that the current into the device was
several amps. They want the product to work first time, every time.
To prevent these kinds of problems test standards have been developed
to test systems for ESD robustness. The best known of these is the IEC
61000-4-2 standard but there are others such as ISO 10605 and SAE
J1113-13 for testing of automotive components. Testing with these
standards allows one to find and correct vulnerability of products to
ESD stress.
While testing systems for ESD robustness is done extensively, the
nature of the tests are often misunderstood. This is especially true
for engineers that are more familiar with the classic device level
tests of Human Body Model (HBM), Machine Model (MM) and Charged Device
Model (CDM) applied to integrated circuits. This article will explain
the intention of ESD tests for both devices and system level, and then
discuss the device level and system level stress waveforms.
Purpose of Tests
The purposes of system level and device level testing are different.
System level testing is intended to ensure that finished products can
survive normal operation. It is not assumed that the user of the
product will take any precautions to lower ESD stress to the product.
The purpose of traditional ESD testing of integrated circuits is very
different. HBM, MM and CDM tests are intended to ensure that integrated
circuits survive the manufacturing process. For example, an integrated
circuit needs to survive saw apart from the wafer, packaging, final
test, shipment to a board assembly facility, placement on a circuit
board with automatic pick and place machinery, and the solder process.
All of these processes are done in a controlled ESD environment that
limits the level of ESD stress to which the device is exposed.
Even when the device is on a circuit board, it is expected that ESD
precautions (such as shipment in ESD safe packaging material) will be
taken to minimize stress to the board. Once the board is in a system,
ESD precautions are no longer assumed. A system level ESD test can
therefore be expected to be a much more severe test than that intended
for an integrated circuit.
The Nature of ESD Tests
ESD tests are intended to simulate real world events, with different
test standards intended to cover different situations. The HBM device
standard is intended to simulate a person becoming charged and
discharging from a bare finger to ground through the circuit under
test. The MM is intended to simulate a charged machine, such as a pick
and place machine, discharging through the device to ground. CDM
simulates an integrated circuit becoming charged and discharging to a
grounded metal surface.
System level tests, such as IEC 61000-4-2 and ISO 10605 replicate a
charged person discharging to a system, similar to HBM testing. The
only conceptual difference between the IEC 61000-4-2 standard and
device level HBM is that for the system test it is assumed that the
person is holding a metal object such as a key or screwdriver. As we
shall see, this produces a very different waveform.
Device Level ESD Waveforms
We will now discuss the individual models and the stress waveforms that
are associated with each standard. Each of the standards is
characterized by a capacitor that is charged and a discharge path.
We will start with the HBM standard, since it is the most popular
device level test. A person’s capacitance to their surroundings is
approximately 100pF, and the HBM standard uses this value to represent
a person. The discharge path includes a person’s skin resistance and
the resistance of the spark, which has been approximated as 1500Ω. The
traditional circuit diagram for HBM is shown in Figure 1. An actual HBM
current waveform is shown in Figure 2.
Figure 1: Basic circuit diagram for HBM and MM
Figure 2: 2000V HBM Current waveform into a short
Note that a characteristic of HBM, and of all ESD standards, is that
the ESD stress is specified by a current waveform into a defined load.
The compliance of the waveform to the standard is determined by
waveform parameters, such as peak current, rise time, percent ringing
and decay time. The values of the resistors, capacitors and inductors
in the circuit diagrams are in fact not specified in the standards;
only the current waveforms, and only “nominal” values for the circuit
elements are in the standards.
Another feature of all of the standards is that the basic circuit
diagram presented for the model will not produce the specified
waveforms. There are always “parasitic” circuit elements that are
needed to create the specified waveforms. The deviation of the
waveforms from the waveform predicted by the simple schematics is on
purpose. All real world test systems have parasitics that can not be
avoided. Standards must reflect systems that can be built in the real
world.
The machine model has a very similar circuit diagram as HBM, and is
shown in Figure 1. The capacitor value is increased to 200pF, and an
approximately 0.8µH inductor replaces the 1500Ω resistor from HBM. The
inductor is not specified in the standards but is needed to produce the
required oscillatory MM waveform. Figure 3 shows an actual, in
specification, waveform for MM. Note that, even though the charging
voltage for the waveform shown in Figure 3 is a tenth that of the HBM
example, the peak current is considerably higher.
Figure 3: 200V MM waveform into a short
CDM is substantially different from HBM and MM. There is no capacitor
even nominally specified in the standard. This makes sense because the
CDM discharge simulates a charged integrated circuit being discharged
to a metal surface. The capacitor is the device’s capacitance to its
surroundings. There are several charged device test methods, but one of
the most popular is the Field Induced CDM (FCDM). A simplified diagram
of a field induced CDM tester is shown in Figure 4.
Figure 4: Diagram of a Field Induced CDM ESD Tester
The tester consists of a field plate that can be raised to a high
voltage. The field plate is covered with a thin insulator. A circuit
placed pin side up on the field plate insulator (dead bug position)
will have a capacitance to the field plate that is dependent on the
size and geometry of the circuit being tested. This is the capacitor
that will be charged. Over the field plate is a grounded plate with a
spring loaded “pogo pin.” The pogo pin is electrically connected to the
ground plane with a low inductance circular 1Ω resistor as well as to a
50Ω cable that can be used to capture the CDM current waveform. The
ground plane and the field plate can be moved relative to each other
under computer control so that the pogo pin can be brought in contact
with the pins of the device on the field plate.
If the capacitance between the integrated circuit and the field plate
is much larger than the capacitance of the integrated circuit to the
ground plane and any other parts of the test system, the potential of
the integrated circuit will track the potential of the field plate. The
test procedure is to place the uncharged integrated circuit on the
insulated field plate and then slowly raise the potential of the field
plate (and consequently the potential of the integrated circuit) to a
high voltage. Touching an IC pin while it is at high potential with the
pogo pin will ground the IC. This will occur very quickly and will
result is a very short duration high current pulse.
The current level of this event is shown for 500V on a JEDEC small
calibration module in Figure 5. The current pulse is over in about 2
ns. This compares to the100s of ns time scales for HBM and MM.
Figure 5: Field Induced CDM waveform of a small JEDEC Module at 500V
System Level ESD Waveforms
As discussed earlier, the IEC 61000-4-2 stress is intended to simulate
a person discharging into a system while holding a metal object such as
a key. Touching with a metal object suggests that, at least for the
early part of the discharge, there will be very little resistance other
than the arc resistance of the discharge. The circuit diagram for the
IEC pulse source as in the specification is shown in Figure 6, and a
schematic view of the waveform, as well as the parameter to
characterize the waveform, are shown in Figure 7.
Figure 6: IEC 61000-4-2 schematic as shown in specification
Figure 7: Schematic diagram of the IEC waveform and the parameters used to characterize the waveform
The IEC waveform uses a C1 capacitor with a nominal value of 150pF
Capacitor (50% larger than the HBM value), and an R1 resistor of
nominal value 330Ω (only 22% of the HBM value). This suggests that the
IEC waveform will have a higher peak current and faster decay time than
an HBM waveform. However, the IEC waveform is not just different in
magnitude; the waveform has a distinctly different shape. This can be
easily seen by comparing the HBM waveform in Figure 2, the schematic
IEC waveform in Figure 7 and a sample IEC compliant waveform shown in
Figure 8.
Figure 8: Waveform from an IEC compliant ESD gun at 4000V
The IEC waveform has a very fast, large amplitude current spike at the
beginning of the waveform. The circuit diagram shown in Figure 6, as it
is presented in the IEC standard, can not create the waveform that the
standard calls for. A superficial examination of the IEC and HBM
circuit diagrams often leads people to expect the waveforms to be
similar. The movement of the relay from one side of the resistor to the
other, and the presence of parasitic capacitance, results in a
significant change in the waveform.
A more realistic circuit diagram is shown in Figure 9. (Pommerenke and
Aidam give a more detailed circuit diagram useful for waveform
simulation [1]) The placement of the relay on the device under test
side of the resistor means that any parasitic capacitance on the device
side of the resistor will be charged before the relay closes. When the
relay closes, the capacitance C2 will discharge into the device under
test with only parasitic inductance and resistance to limit the
current. This produces the large initial current spike in the IEC
waveform. The presence of the spike in the required IEC waveform
requires the parasitic capacitor C2. In contrast, HBM parasitic
capacitance on the device under test side of the 1500Ω resistor will
not be charged before the relay closure and no initial current spike is
produced.
Figure 9: More realistic IEC 61000-4-2 schematic
The dominance of the “parasitic” capacitor C2 on the initial current
pulse is easily illustrated if the IEC 61000-4-2 waveform is compared
with the waveforms for the automotive system level test ISO 10605. The
ISO test uses the same type of ESD gun as the IEC test but the resistor
R1 is changed from 330Ω to 2000Ω, while the 150pF C1 capacitor is
either left at 150pF or changed to 330pF, depending on the system being
tested. Waveforms from the same ESD gun with the different R1 and C1
values at 4000V are shown in Figure 10. The initial peak is identical
because it is dominated by C2 and I2; but, after the first 5 to 10 ns,
the waveform starts to depend on C1 and R2. The difference between the
two ISO waveforms only becomes obvious at longer times, such as in
Figure 11 for stress at 8000V.
Figure 10: Comparison of ISO 61000-4-2 waveform with ISO 10605 waveforms with both 150pF and 330pF capacitances at 4000V
Figure 11: Comparison of ISO 61000-4-2 waveform with ISO 10605 waveforms with both 150pF and 330pF capacitances at 8000V
System and Device Waveform Comparison
The difference between system and device level stress becomes obvious
when the current waveforms are displayed on the same plot as they are
in Figure 12, and with an expanded time scale in Figure 13. 500V CDM
and 2000V HBM are the most common target levels for product acceptance
for ESD tests on integrated circuits, and it is often hard to obtain
these levels of robustness especially on modern high speed circuits.
However, 2000V IEC stress is the minimum test level specified for
system testing. Even with this minimum level of stress for IEC, the
system level currents are several times larger than the HBM stress,
although the HBM stress does continue for somewhat longer than the IEC
stress. The peak CDM current comes closer to the peak current of the
IEC stress and has similar rise time, but the duration of the IEC
stress is almost 2 orders of magnitude longer. In some ways, the IEC
system level stress looks similar to a combination of the fast rise
time peak of CDM and the longer lasting current from HBM. As the stress
levels for system level test are raised from the minimum level of 2000V
to 8000V for IEC contact discharge, the higher level of stress for
system level testing becomes even greater.
Figure 12: Comparison of IEC, HBM and CDM waveforms
Figure 13: Comparison of IEC, HBM and CDM at an expanded time scale
Summary
The current waveform stresses for some of the most common device and
system level tests have been presented. It has been shown how system
level testing, especially for IEC 61000-4-2, is much more severe than
device level test, combining both the fast rise time and high peak
current of a CDM event with the more long lasting currents of the HBM
test. Knowledge of the waveform, no mater how complete, does not fully
define the test. This is especially true for system level ESD testing.
In order to upset or damage a system, the stress must reach a sensitive
component. The stress must also be done in a way that approximates a
real world event; otherwise, the test does not provide value.
Robert Ashton is a senior protection and compliance specialist at ON
Semiconductor, and can be reached at Robert.Ashton@onsemi.com.
References
-
D. Pommerenke and M. Aidam, “To what Extent do Contact Mode and
Indirect ESD Test Methods Reproduce Reality?” 1995 EOS/ESD Symposium,
pp. 101-109.